 +_____________________________________________________________________
 ] AUTHOR:            ]                             ] SMS:  B28716     ]
 ] S. VENITSKY        ]    BFS PROGRAM NOTE         ] DR:   109614     ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE ( )  USER NOTE (X) ] DATE:  06/15/94  ]
 ] RID/ (310)922-1921 ]      RELEASE NOTE ( )       ]                  ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ]   OI23 & SUBS                 ]  CREW (X)  GROUND (X)  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ]           MAJOR SOFTWARE AREA:            ] OPS MODES AFFECTED:     ]
 ]BSL( ) BSS(X) GNC( ) SEQ( ) SM/SP( ) IPL( )]    0, 1, 3, 6           ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA:    PAYLOAD BAY DOORS                             ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS:  MG038101 / 3.12.2, 3.12.2.1                   ]
 ]_____________________________________________________________________]
 ] TITLE:  PBD MANUAL ITEM ENTRIES MAY CAUSE PROBLEM IN AUTO MODE      ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ] THE PAYLOAD BAY DOOR (PBD) AUTO SEQUENCE MAY OPERATE OUT OF ORDER   ]
 ] IF IT IS PRECEDED BY THE EXECUTION OF A MANUAL ITEM ENTRY THAT IS   ]
 ] OUT OF THE NORMAL SEQUENCE ORDER.  IF THE OUT OF ORDER CONDITION    ]
 ] OCCURS DURING AN AUTO SEQUENCE OPEN OPERATION, THE SEQUENCE WILL    ]
 ] TERMINATE WITH A PBD SEQ FAIL MESSAGE.  DURING THE AUTO SEQUENCE    ]
 ] CLOSE SEQUENCE, NO MESSAGE WILL BE ANNUNCIATED AND THE SEQUENCE     ]
 ] WILL ATTEMPT TO COMPLETE.                                           ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ] USER RESPONSE:                                                      ]
 ]                                                                     ]
 ] IF THE AUTO SEQUENCE OPERATES OUT OF ORDER, THE USER SHOULD RESPOND ]
 ] AS FOLLOWS:                                                         ]
 ]                                                                     ]
 ]    1.  STOP THE AUTO SEQUENCE.                                      ]
 ]    2.  CORRECT THE OUT OF ORDER MANUAL ITEM ENTRY TO ITS REQUIRED   ]
 ]        CONFIGURATION STATE.                                         ]
 ]    3.  RESET THE SEQUENCE TO THE PROPER LATCH/DOOR GROUP BY MANUAL  ]
 ]        ITEM ENTRY.                                                  ]
 ]    4.  CONTINUE THE SEQUENCE IN EITHER AUTO OR MANUAL MODE.         ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]RI: <S> G. ALBRIGHT       DATE 06/20/94]                             ]
 ]    --------------------      ---------]                             ]
 ]FDSD:   W. R. PRUETT      DATE 07/22/94]                             ]
 ]     -------------------      ---------] DARRELL E. STAMPER 08/09/94 ]
 ]PF MGR:  JAMES BAGWELL    DATE 07/20/94]------------------- -------- ]
 ]       -----------------      ---------] CHAIRMAN, SASCB      DATE   ]
 ]_____________________________________________________________________]
 @