 +_____________________________________________________________________
  AUTHOR:                                          SMS: B20068      
  C. SEBASTIAN           BFS PROGRAM NOTE          DR:  109628      
 ____________________                             __________________
  ORG/PHONE:          OPS NOTE (X)  USER NOTE ( )  DATE: 9/22/94    
  RID/922-3747             RELEASE NOTE ( )        REV :            
 ___________________________________________________________________
  OI/FLIGHT EFFECTIVITY:          USER AFFECTED:                     
   OI-23 AND SUBS                 CREW (X)  GROUND (X)  DUMP ONLY ( )
 ____________________________________________________________________
            MAJOR SOFTWARE AREA:             OPS MODES AFFECTED:     
 BSL( ) BSS(X) GNC( ) SEQ( ) SM/SP( ) IPL( )      OPS 0              
 _____________________________________________________________________
  SOFTWARE SUB-AREA:  DISP                                            
 _____________________________________________________________________
  PRINCIPAL FUNCTIONS:         STS 83-0020 / 3.5                      
 _____________________________________________________________________
  TITLE:                                                              
       BIG X ON BFS DISPLAY ON TRANSITION FROM HALT                   
 _____________________________________________________________________
  DESCRIPTION:                                                        
                                                                      
    A BIG X BUT NO POLL FAIL MESSAGE MAY BE ON THE BFS COMMANDED      
    DEU(S) AFTER MODING FROM HALT TO STANDBY OR TRANSITIONING         
    TO OPS 0.                                                         
                                                                      
                                                                      
 _____________________________________________________________________
  USER RESPONSE:                                                      
                                                                      
  1. VERIFY BIG X AND NO POLL FAIL MESSAGE OCCURS ON A HALT TO        
     STANDBY TRANSITION OR OPS 0 TRANSITION.                          
  2. VERIFY MUMDONE = 0000 IN VP DOWNLIST. IF IT IS NOT AVAILABLE     
     THEN PERFORM A HISAM DUMP AND VERIFY MUMDONE LOCATION = 0000.    
     (THIS IS THE DR 109628 CONDITION)                                
  3. IF DR CONDITION EXISTS, THEN RE-IPL THE BFS, RE-INSTALL THE      
     THE VP DOWNLIST SELECT, AND THEN CONTINUE.                       
                                                                      
     NOTE: THE MUMDONE LOCATION MAY PERIODICALLY REFLECT 0000, BUT    
     WILL BE A TRANSIENT INDICATION THAT IS EXPECTED. THE CONDITION   
     DESCRIBED ABOVE IS ONLY PRESENT FOR A MUMDONE LOCATION THAT      
     REMAINS 0000.                                                    
                                                                      
                                                                      
 _____________________________________________________________________
 CONCURRENCE:                           APPROVAL:                    
 RI: <S> J. AGRES FOR GWA  DATE 10/14/94                             
     --------------------      ---------                             
 FDSD:   W. R. PRUETT      DATE 10/18/94                             
      -------------------      --------- DARRELL E. STAMPER 10/18/94 
 PF MGR: DAVID STEPHENSON  DATE 10/18/94------------------- -------- 
        -----------------      --------- CHAIRMAN, SASCB      DATE   
 _____________________________________________________________________
 @