 +_____________________________________________________________________
 ] AUTHOR:            ]                             ] SMS: B02831      ]
 ] W. BERTRAND        ]    BFS PROGRAM NOTE         ]                  ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE ( )  USER NOTE (X) ] DATE:            ]
 ] RI DNY/2144        ]      RELEASE NOTE ( )       ]12/05/85 REV      ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ]  OI07 AND SUBS                ]  CREW (X)  GROUND ( )  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ]           MAJOR SOFTWARE AREA:            ] OPS MODES AFFECTED:     ]
 ]BSL( ) BSS( ) GNC( ) SEQ(X) SM/SP(X) IPL( )]1                        ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA: MPS, DUMP, OPS                                   ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS: MG038120/3.3.1.6                               ]
 ]_____________________________________________________________________]
 ] TITLE: NO TAL MPS DUMP IN OPS 1                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ]   THE BFS INCORPORATION OF CR 69995D (SMS B02809) DELETED           ]
 ]   THE OPS 1 MANUALLY INITIATED TAL MPS DUMP, AND ADDED THE          ]
 ]   OPS 3 AUTOMATIC TAL MPS DUMP, INITIATED UPON TRANSITION           ]
 ]   INTO MM 304.  IF BFS IS ENGAGED AFTER THE PASS HAS INITIATED      ]
 ]   A TAL MPS DUMP IN MM 104, BFS WILL NOT COMPLETE THE TAL MPS       ]
 ]   DUMP IN OPS 1 AND THE BODY FLAP LAMP WILL NOT GO OUT(LIGHT        ]
 ]   IS THE CUE TO PRO TO MM304). MPS HELIUM WILL BE LOST OVER-        ]
 ]   BOARD THROUGH THE MPS MANIFOLD REPRESS VALVES.                    ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]USER RESPONSE:                                                       ]
 ]                                                                     ]
 ]   IF BFS IS ENGAGED IN A TAL ABORT IN MM 104 AFTER THE CREW         ]
 ]   HAS MANUALLY INITIATED A TAL MPS DUMP IN PASS, PERFORM THE        ]
 ]   THE FOLLOWING: IF THE BODY FLAP LAMP IS STILL ON, PRO BFS         ]
 ]   TO MM304 AND CLOSE THE LO2 AND LH2 MANIF PRESS SWITCHES ON        ]
 ]   PANEL R4 TO PREVENT LOSS OF HELIUM DURING ENTRY. AT VEL REL       ]
 ]   OF 4.4K FPS, OPEN THE LO2 AND LH2 MANIF PRESS SWITCHES TO         ]
 ]   SUPPLY HELIUM FOR THE ENTRY PURGE.                                ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]RI:<S> K. MORRIS          DATE 12-05-85]                             ]
 ] --------------------         ---------]                             ]
 ]SSD:  SAM ANKNEY          DATE 08-10-88]                             ]
 ] --------------------         ---------]  JACK G. BOYKIN    08-17-88 ]
 ]PF MGR:  D.W. MAY         DATE 08-05-88]------------------- -------- ]
 ]       -----------------      ---------] CHAIRMAN, SASCB      DATE   ]
 ]_____________________________________________________________________]
 @