 +_____________________________________________________________________
 ] AUTHOR:            ]                             ] DR:              ]
 ]  M. MILLER         ]    PASS PROGRAM NOTE        ]        63385     ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE ( )  USER NOTE (X) ] DATE:  04/29/86  ]
 ]  LSIS/282-7167     ]      RELEASE NOTE( )        ] REV A: 07/03/95  ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ]  OI-07 AND SUBS               ]  CREW ( )  GROUND (X)  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ]        MAJOR SOFTWARE AREA:       ] OPS MODES AFFECTED:             ]
 ]SSW ( )  GNC ( )  VU (X)  SM/PL ( )] PL9                             ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA: MMU, LDB                                         ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS: V5.1.12                                        ]
 ]_____________________________________________________________________]
 ] TITLE:        ERRONEOUS RESPONSE ON LDB DUMP  REQUEST               ]
 ]         WHEN REQUESTED LOADBLOCK IS TOO LONG                        ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ] IF AN LDB REQUEST IS MADE TO READ AND DUMP A LOADBLOCK IN P9        ]
 ] AND THE LENGTH OF THE REQUESTED LOADBLOCK IS GREATER THAN           ]
 ] 16,384 HALFWORDS THE RESPONSE WILL BE: AN ERROR CODE OF 7 FOLLOWED  ]
 ] BY STALE DATA.                                                      ]
 ]                                                                     ]
 ] THE REQUESTED LOADBLOCK HAS NOT BEEN READ FROM MM INTO THE          ]
 ] MM UTILITY BUFFER (CDHV_BLOCKS), SO THE DATA (CONTENTS OF THE       ]
 ] MM UTILITY BUFFER) THAT IS SENT DOWN THE LDB IS NOT THE             ]
 ] CONTENTS OF THE REQUESTED PHASE AND LOADBLOCK.                      ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]USER RESPONSE:                                                       ]
 ]                                                                     ]
 ] THE DATA SENT AS CONTENTS OF THE REQUESTED PHASE AND LOADBLOCK      ]
 ] SHOULD BE IGNORED.                                                  ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]LSIS:   JEAN L. ZOPHY     DATE 08/15/95]                             ]
 ]     ------------------       ---------]                             ]
 ]ASD:   ERIC C. BINGHAM    DATE 08/15/95]                             ]
 ]     ------------------       ---------] DARRELL E. STAMPER 08/24/95 ]
 ]PF MGR: ERIC C. BINGHAM   DATE 08/15/95]------------------- -------- ]
 ]       ----------------       ---------] CHAIRMAN, SASCB      DATE   ]
 ]_______________________________________]_____________________________]
 @