 +_____________________________________________________________________
 ] AUTHOR:            ]                             ] DR:              ]
 ] R. STRACHAN        ]    PASS PROGRAM NOTE        ]    55336         ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE ( )  USER NOTE (X) ] DATE: 02/14/85   ]
 ] IBM/282-7953       ]      RELEASE NOTE( )        ]                  ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ] OI05 AND SUBS                 ]  CREW (X)  GROUND ( )  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ]        MAJOR SOFTWARE AREA:       ] OPS MODES AFFECTED:             ]
 ]SSW ( )  GNC (X)  VU ( )  SM/PL ( )]         G1                      ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA: DISPLAY, SEQUENCERS                              ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS:  4.165, 4.114                                  ]
 ]_____________________________________________________________________]
 ] TITLE:                                                              ]
 ]       EVENT TIMER DOES NOT AUTOMATICALLY RESET AT MECO              ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ]     THE INTENT OF THE SOFTWARE CHANGES IN CR59414A AND CR59722      ]
 ] WAS TO CAUSE THE EVENT TIMER TO AUTOMATICALLY RESET AT MECO,        ]
 ] THEREBY PROVIDING A MECO PLUS TIMER WITHOUT THE NEED FOR CREW       ]
 ] ACTION.  THE CURRENT HARDWARE DESIGN WILL NOT PROCESS AN            ]
 ] EVENT TIMER START COMMAND AT THE LIFTOFF COMMAND TIMER INTERFACE    ]
 ] SUBSEQUENT TO LIFTOFF UNLESS THE TIMER IS POWERED DOWN OR A STOP    ]
 ] COMMAND IS RECEIVED TO RESET THE LIFTOFF COMMAND.  THEREFORE,       ]
 ] THE TIMER DOES NOT RESET AT MECO, BUT INSTEAD CONTINUES TO COUNT.   ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]USER RESPONSE:                                                       ]
 ]                                                                     ]
 ]     THE TIMER CAN STILL BE RESET MANUALLY AT MECO AS WAS TRUE       ]
 ] BEFORE THESE CRS WERE IMPLEMENTED                                   ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]IBM: WYATT COOPER         DATE 9/12/88 ]                             ]
 ]    --------------------      ---------]                             ]
 ]SSD: SAM ANKNEY           DATE 9/21/88 ]                             ]
 ]    --------------------      ---------] JACK G BOYKIN       9/22/88 ]
 ]PF MGR: DON PREVETT       DATE 9/19/88 ]------------------- -------- ]
 ]       -----------------      ---------] CHAIRMAN, SASCB      DATE   ]
 ]_______________________________________]_____________________________]
 @
