 +_____________________________________________________________________
 ] AUTHOR:            ]                             ] DR:              ]
 ]  K. M. NUZENSKI    ]    PASS PROGRAM NOTE        ]      55146       ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE ( )  USER NOTE (X) ] DATE:  05/16/84  ]
 ]  IBM/282-7760      ]      RELEASE NOTE( )        ] REV D: 09/25/90  ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ]  STS-14 AND SUBS              ]  CREW (X)  GROUND ( )  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ]        MAJOR SOFTWARE AREA:       ] OPS MODES AFFECTED:             ]
 ]SSW ( )  GNC (X)  VU ( )  SM/PL ( )]          G1, G3                 ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA: DED-DISP, AVVI, AMI                              ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS: 4.105, 4.106                                   ]
 ]_____________________________________________________________________]
 ] TITLE:                                                              ]
 ] AVVI & AMI DED-DISPS NOT INIT. IN MM101 & MM301                     ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ]      AS PART OF THE INITIALIZATION PROCESS FOR OPS 1 AND OPS 3      ]
 ] THE COMMAND WORDS FOR THE AVVI & AMI ARE INITIALIZED TO THE SCALE   ]
 ] VALUES REQUIRED TO SET THE DEDICATED DISPLAYS TO LAUNCH/REENTRY     ]
 ] CONDITIONS (AS PER CR 29768B). THE CONTROL WORDS WHICH ARE USED BY  ]
 ] THE AVVI AND AMI DEVICES TO IDENTIFY VALID COMMAND DATA ARE NOT     ]
 ] BEING SET.  CONSEQUENTLY THE COMMAND WORDS ARE NOT BEING PROCESSED  ]
 ] BY THE AVVI AND AMI HARDWARE.  THE AVVI AND AMI WILL REMAIN AT THEIR]
 ] PREVIOUS POSITIONS UPON ENTRY INTO MM101 AND MM301.  THE CONTROL    ]
 ] WORDS ARE BEING SET CORRECTLY FOR MM102, MM103, MM601, MM602,       ]
 ] MM603, MM304 & MM305 AND DYNAMIC DATA WILL BE PROCESSED PROPERLY.   ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]USER RESPONSE:                                                       ]
 ]                                                                     ]
 ]        NONE.                                                        ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]IBM: PATTI A. THORNTON    DATE 11/06/90]                             ]
 ]    --------------------      ---------]                             ]
 ]FDSD:  W. R. PRUETT       DATE 11/06/90]                             ]
 ]     -------------------      ---------] DARRELL E. STAMPER 11/09/90 ]
 ]PF MGR:  A. T. HIEMER     DATE 11/09/90]------------------- -------- ]
 ]                                       ] CHAIRMAN, SASCB      DATE   ]
 ]_______________________________________]_____________________________]
 @