 +_____________________________________________________________________
 ] AUTHOR:            ]                             ] DR:              ]
 ] T. METCALF         ]    PASS PROGRAM NOTE        ]    54012         ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE ( )  USER NOTE (X) ] DATE:            ]
 ] DEV/282-8436       ]      RELEASE NOTE( )        ] SEP. 1987        ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ] OI02 AND SUBS                 ]  CREW (X)  GROUND ( )  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ]        MAJOR SOFTWARE AREA:       ] OPS MODES AFFECTED:             ]
 ]SSW (X)  GNC ( )  VU ( )  SM/PL ( )] 0, G1, G2, G3, G6, G8, G9, S2,  ]
 ]                                   ] S4, PL9                         ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA: IPL                                              ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS: SS2, SANU                                      ]
 ]_____________________________________________________________________]
 ] TITLE:                                                              ]
 ] CAM LIGHT ON/OFF DURING SUCCESSFUL IPL                              ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ] THE BOOTSTRAP LOADER WILL CAUSE THE I-FAIL LIGHT TO TURN ON AND A   ]
 ] MASTER ALARM WHEN LOADING THE IPL PROGRAM.  FOLLOWING THE           ]
 ] SUCCESSFUL LOAD OF THE IPL PROGRAM INTO GPC MEMORY, THE BOOTSTRAP   ]
 ] WILL RESET THE I-FAIL LIGHT AND PASS CONTROL TO THE IPL PROGRAM     ]
 ] TO CONTINUE THE IPL.  THE I-FAIL LIGHT SHOULD BE TURNED OFF         ]
 ] WITHIN A FEW SECONDS IF THERE ARE NO BOOTSTRAP LOADER PROBLEMS.     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ] USER RESPONSE:                                                      ]
 ]                                                                     ]
 ] IGNORE I-FAIL CAM LIGHTS DURING IPL IF THE LIGHT COMES ON AND THEN  ]
 ] GOES OFF AND RESET THE MASTER ALARM.  IF THE I-FAIL LIGHT STAYS ON, ]
 ] THEN THE IPL PROCESS HAS FAILED IN THE BOOTSTRAP LOADER.  PERFORM   ]
 ] STANDARD IPL-FAILURE PROCEDURES IN THIS CASE.                       ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]IBM: WYATT COOPER         DATE 8/4/88  ]                             ]
 ]    --------------------      ---------]                             ]
 ]SSD: SAM ANKNEY           DATE 8/10/88 ]                             ]
 ]    --------------------      ---------] JACK BOYKIN         8/17/88 ]
 ]PF MGR: MICHAEL BRIEDEN   DATE 8/8/88  ]------------------- -------- ]
 ]       -----------------      ---------] CHAIRMAN, SASCB      DATE   ]
 ]_______________________________________]_____________________________]
 @