 +_____________________________________________________________________
 ] AUTHOR:            ]                             ] DR:              ]
 ] SOLLINGER          ]    PASS PROGRAM NOTE        ]     37503        ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE ( )  USER NOTE (X) ] DATE:            ]
 ] DEV/282-8461       ]      RELEASE NOTE( )        ] AUG. 1987        ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ] REL 18 AND SUBS               ]  CREW (X)  GROUND (X)  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ]        MAJOR SOFTWARE AREA:       ] OPS MODES AFFECTED:             ]
 ]SSW (X)  GNC ( )  VU ( )  SM/PL ( )] 0, G1, G2, G3, G6, G8, G9, S2,  ]
 ]                                   ] S4, PL9                         ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA: SPEC, DEU                                        ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS: SDEU                                           ]
 ]_____________________________________________________________________]
 ] TITLE:                                                              ]
 ] UNABLE TO RESUME SPEC FROM A FAILED DEU                             ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ] IF A SPECIALIST FUNCTION (SPEC) IS ACTIVE ON A DISPLAY ELECTRONICS  ]
 ] UNIT (DEU) THAT FAILS, THE CAPABILITY TO RESUME THE SPEC IS LOST.   ]
 ] THE SOFTWARE PROVIDES NO CAPABILITY TO RESUME THE SPEC ON ANOTHER   ]
 ] DEU. THE SPEC IS NOT "LOST" AT ANOTHER DEU. HOWEVER, THE SPEC IS    ]
 ] CHARGED TO THE ACTIVE MAJOR FUNCTION (MF) AS ONE OF TWO SPEC'S THAT ]
 ] CAN BE ACTIVE AT ONE TIME.                                          ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]USER RESPONSE:                                                       ]
 ]                                                                     ]
 ] IF A DEU FAILURE CAUSES A SPEC TO REMAIN ACTIVE, THE SPEC CAN BE    ]
 ] CANCELLED (RESUMED) BY INITIATING ONE OF THE FOLLOWING PROCEDURES:  ]
 ]                                                                     ]
 ] A.  DO AN OPERATIONAL SEQUENCE (OPS) TRANSITION TO CAUSE THE SPEC   ]
 ]     TO BE CANCELLED.                                                ]
 ]                                                                     ]
 ] B.  USE THE DEU EQUIVALENT MESSAGE CAPABILITY OF THE LAUNCH DATA    ]
 ]     BUS (LDB) OR UPLINK TO ENTER A RESUME TO THE FAILED DEU AND     ]
 ]     THEN BRING THE SPEC UP ON ANOTHER DEU.                          ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]IBM: WYATT COOPER         DATE 8/4/88  ]                             ]
 ]    --------------------      ---------]                             ]
 ]SSD: SAM ANKNEY           DATE 8/10/88 ]                             ]
 ]    --------------------      ---------] JACK BOYKIN         8/17/88 ]
 ]PF MGR: MICHAEL BRIEDEN   DATE 8/8/88  ]------------------- -------- ]
 ]       -----------------      ---------] CHAIRMAN, SASCB      DATE   ]
 ]_______________________________________]_____________________________]
 @