 +_____________________________________________________________________
  AUTHOR:                                          DR:              
  S. EHMRY               PASS PROGRAM NOTE            109223        
 ____________________                             __________________
  ORG/PHONE: USA/PASS OPS NOTE (X)  USER NOTE ( )  DATE:            
  (281)282-4305            RELEASE NOTE( )                 06/15/99 
 ___________________________________________________________________
  OI/FLIGHT EFFECTIVITY:          USER AFFECTED:                     
  OI-28                           CREW (X)  GROUND (X)  DUMP ONLY ( )
 ____________________________________________________________________
         MAJOR SOFTWARE AREA:        OPS MODES AFFECTED:             
 SSW ( )  GNC ( )  VU ( )  SM/PL (X) S2, S4                          
 _____________________________________________________________________
  SOFTWARE SUB-AREA:  PSP COMM                                        
 _____________________________________________________________________
  PRINCIPAL FUNCTIONS:  S4.9                                          
 _____________________________________________________________________
  TITLE:  PSP INCOMPLETE/REJECTED FLAG INCONSISTENCY WITH             
          REINITIALIZATION LOAD                                       
 _____________________________________________________________________
  DESCRIPTION:  DURING THE PAYLOAD SIGNAL PROCESSOR (PSP) REJECT      
  PROCESSING DURING PSP COMMUNICATION, A REINITIALIZE LOAD FAILURE    
  COULD CAUSE EITHER THE PSP LOAD REJECTED (V92X1102X) FLAG OR THE PSP
  CMD LOAD TRANSFER INCOMPLETE (V92X1116X) FLAG TO BE SET.            
                                                                      
  IF THE PREVIOUS LOAD TO THE REINITIALIZE LOAD FAILURE SENT DATA     
  WORDS TO THE PSP, THEN THE REINITIALIZE LOAD FAILURE WILL CAUSE THE 
  PSP CMD LOAD TRANSFER INCOMPLETE FLAG TO BE SET AND 'INCP' TO BE    
  DISPLAYED IN THE PSP STATUS FIELD OF SPEC 62.  IF THE PREVIOUS LOAD 
  DID NOT SEND DATA WORDS, THEN THE REINITIALIZE LOAD FAILURE WILL    
  CAUSE THE PSP LOAD REJECTED FLAG TO BE SET AND 'RJCT' TO BE         
  DISPLAYED                                                           
                                                                      
  THE PSP LOAD REJECTED FLAG SHOULD ALWAYS BE SET FOR A REINITIALIZE  
  LOAD FAILURE AND SHOULD NOT BE BASED ON THE PREVIOUS LOAD SENT TO   
  THE PSP.                                                            
 _____________________________________________________________________
 USER RESPONSE:                                                       
                                                                      
  ONCE A REJECT IS SEEN, THROUGH EITHER THE PSP CMD LOAD TRANSFER     
  INCOMPLETE OR PSP LOAD REJECTED FLAGS BEING SET, SOME GRANULARITY   
  OF THE REJECTION MAY BE DETERMINED BY CPVS_TCS_PSP_TRANSFER_STATUS  
  (V92J1119C) WHICH IS MADE AVAILABLE FOR DOWNLIST.                   
                                                                      
  OTHERWISE, THE USER SHOULD BE AWARE THAT A REINITIALIZE LOAD FAILURE
  MAY BE SEEN THROUGH EITHER THE PSP LOAD REJECTED FLAG OR THE PSP CMD
  LOAD TRANSFER INCOMPLETE FLAG BEING SET.                            
 _____________________________________________________________________
 CONCURRENCE:                           APPROVAL:                    
 USA/PASS: JOHN MAGLEY     DATE 06/29/99                             
         ----------------      ---------                             
 CHAIR:    KENNETH HILL    DATE 06/29/99                             
         ----------------      --------- DARRELL E. STAMPER 06/30/99 
 PF MGR:   ALAN OGLETREE   DATE 06/25/99------------------- -------- 
         ----------------      --------- CHAIRMAN, SASCB      DATE   
 ____________________________________________________________________
 @