 +_____________________________________________________________________
 ] AUTHOR:            ]                             ] DR:              ]
 ] PAUL TICE          ]    PASS PROGRAM NOTE        ]       107292     ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE (X)  USER NOTE ( ) ] DATE:  01/02/96  ]
 ] SSOAS/(281)335-2239]      RELEASE NOTE( )        ] REV A: 04/03/97  ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ] OI-23 THRU OI-26B             ]  CREW ( )  GROUND (X)  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ]        MAJOR SOFTWARE AREA:       ] OPS MODES AFFECTED:             ]
 ]SSW (X)  GNC ( )  VU ( )  SM/PL ( )]       G1, G2, G3, G6, G8        ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA: FCOS, I/O                                        ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS: SBIO                                           ]
 ]_____________________________________________________________________]
 ] TITLE:                                                              ]
 ]  I/O ERROR ON FF1-4 CARD 14 A/D BITE READ GETS LOGGED INCORRECTLY   ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ] IF AN I/O ERROR OCCURS ON THE HFE INPUT I/O TRANSACTION'S MDM       ]
 ] FF1-4 CARD 14 A/D CONVERTER BITE 4 READ, ONLY THE COMMANDER GPC     ]
 ] WILL PLACE THE CORRECT BCE ELEMENT NUMBER FOR THE MDM FF1-4 PROM    ]
 ] SEQUENCE 2-6 READ (I.E., 10, 13, 16, 19) IN ITS I/O ERROR LOG       ]
 ] ENTRY.  ANY RS LISTENER GPC(S) WILL PLACE 253 (X"FD") IN THEIR I/O  ]
 ] ERROR LOG ENTRIES FOR THE BCE ELEMENT NUMBER.                       ]
 ]                                                                     ]
 ] THIS IS ONLY AN I/O ERROR LOGGING PROBLEM VISIBLE IN THE DOWNLIST.  ]
 ] THE CORRECT HFE MDM FF1-4 PROM SEQUENCE 2-6 COMMFAULT AND BYPASS    ]
 ] ARE SET.  IN ADDITION, THE CORRECT FAULT MESSAGE "BCE STRG 1-4 B"   ]
 ] IS ANNUNCIATED SHOULD 2 CONSECUTIVE I/O ERRORS OF THIS TYPE OCCUR.  ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]USER RESPONSE:                                                       ]
 ]                                                                     ]
 ] NONE.  THE USER SHOULD BE AWARE OF THE UNIQUE SIGNATURE THAT IS     ]
 ] PLACED IN ANY LISTENER RS GPC'S I/O ERROR LOG ENTRY FOR THIS TYPE   ]
 ] OF ERROR.                                                           ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]SSOAS:  JOHN MAGLEY       DATE 05/06/97]                             ]
 ]      ------------------      ---------]                             ]
 ]ASD:   ERIC C. BINGHAM    DATE 05/12/97]                             ]
 ]      ------------------      ---------] MELVIN R. ROTHER   06/06/97 ]
 ]PF MGR: KAYLENE F. KINDT  DATE 05/12/97]------------------- -------- ]
 ]       -----------------      ---------] CHAIRMAN, SASCB      DATE   ]
 ]_______________________________________]_____________________________]
 @