 +_____________________________________________________________________
 ] AUTHOR:            ]     RECONFIGURATION         ] DR: 107266       ]
 ] A. DOAN            ]       PROGRAM NOTE          ] SMS: B20071      ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE (X)  USER NOTE ( ) ] DATE: 04/02/96   ]
 ] (310) 922-1692     ]      RELEASE NOTE( )        ]                  ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ] OI-25 (STS-79R1 ONLY)         ]  CREW (X)  GROUND ( )  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ] MAJOR SOFTWARE AREA:    PASS( ) BFS(X)] OPS MODES AFFECTED:         ]
 ] SSME**( ) DEU**( ) T&G( ) DFL/FPL**( )]                             ]
 ] TFL**( ) TCS**( ) I-LOAD( ) LEVEL C(X)] 0,1,3 AND 6                 ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA: DISP, PAYLOADS                                   ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS: JSC19478-79/6.3                                ]
 ]_____________________________________________________________________]
 ] TITLE: DISCRETE MDM DATA ERRONEOUSLY DISPLAYED ON BFS SPEC 206      ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ] THE FOLLOWING MEASUREMENTS ARE DISPLAYED AS FLASHING AND OVERBRIGHT ]
 ] WHEN DRIVEN TO THE LOGIC 1 STATE:                                   ]
 ]                                                                     ]
 ]     P47X2009YV FSS DISCHARGED                                       ]
 ]     P47X2011YV MULTI-BOTTLE HALON DISCHARGE                         ]
 ]     P47X2017YV SMOKE SEN A ALARM                                    ]
 ]     P47X2019YV SMOKE SEN B ALARM                                    ]
 ]     P47X2024YV FSS ARM/SAFE (MCP)                                   ]
 ]     P47X2025YV FSS ARM/SAFE (FSCU)                                  ]
 ]                                                                     ]
 ] THE LEVEL C REQUIREMENTS FOR STS-79 RECON1 INDICATE THESE           ]
 ] MEASUREMENTS DO NOT REQUIRE THE FLASHING OR OVERBRIGHT INTENSITY    ]
 ] CAPABILITIES.                                                       ]
 ]_____________________________________________________________________]
 ]USER RESPONSE:                                                       ]
 ]                                                                     ]
 ]  NONE.                                                              ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]RID:<S> T. MCCLAIN        DATE 04/17/96]                             ]
 ]    --------------------      ---------]                             ]
 ]MOD:    DAVID GRAHAM      DATE 06/04/96]                             ]
 ]    --------------------      ---------] DARRELL E. STAMPER  06/05/96]
 ]SW MGR:  HEIBERT EPPS     DATE 06/04/96]------------------- -------- ]
 ]       -----------------      ---------] CHAIRMAN, SASCB      DATE   ]
 ]_______________________________________]_____________________________]
 @