 +_____________________________________________________________________
 ] AUTHOR:            ]                             ] DR:              ]
 ] ALAN OGLETREE      ]    PASS PROGRAM NOTE        ]      104328      ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE ( )  USER NOTE (X) ] DATE:            ]
 ] IBM/282-8440       ]      RELEASE NOTE( )        ]      02/03/92    ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY:        ]  USER AFFECTED:                     ]
 ]   OI-22 AND SUBS              ]  CREW (X)  GROUND ( )  DUMP ONLY ( )]
 ]_______________________________]_____________________________________]
 ]        MAJOR SOFTWARE AREA:       ] OPS MODES AFFECTED:             ]
 ]SSW ( )  GNC ( )  VU ( )  SM/PL (X)]    S2, S4                       ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA:  RMS                                             ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS:  R4.15 (SYSTEM HEALTH MONITOR FUNCTION)        ]
 ]_____________________________________________________________________]
 ] TITLE:                                                              ]
 ]     NO "CHECK CRT" LIGHT FOR RMS JOINT SLIP CHECK ANNUNCIATION      ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ] THE "CHECK CRT" INDICATOR LIGHT ON THE RMS CAUTION AND WARNING      ]
 ] MATRIX (D&C PANEL A8U) WILL NOT BE CONTINUOUSLY ILLUMINATED         ]
 ] WHEN AN RMS JOINT SLIP CHECK ANNUNCIATION OCCURS.   ALL OTHER       ]
 ] ASSOCIATED ANNUNCIATIONS -- RMS MASTER ALARM, SM TONE, SM MESSAGE,  ]
 ] AND DOWNLIST INDICATORS -- WILL BE GENERATED AS EXPECTED WHEN AN    ]
 ] RMS JOINT SLIP CHECK ANNUNCIATION OCCURS.                           ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]USER RESPONSE:                                                       ]
 ]                                                                     ]
 ] BE AWARE THAT THE "CHECK CRT" LIGHT WILL NOT BE CONTINUOUSLY ILLU-  ]
 ] MINATED WHEN A RMS JOINT SLIP CHECK ANNUNCIATION OCCURS.  OTHER     ]
 ] INDICATIONS -- MOST NOTABLY THE SM MESSAGE "PDRS SLIP XX" (WHERE XX ]
 ] IS THE JOINT SY, SP, ETC.) -- WILL PROVIDE THE NEEDED INSIGHT AS TO ]
 ] WHAT CONDITION CAUSED THE ANNUNCIATION.                             ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]IBM:  PATTI A. THORNTON   DATE 03/17/92]                             ]
 ]    --------------------      ---------]                             ]
 ]FDSD:  ROBERT N. HINSON   DATE 03/18/92]                             ]
 ]     -------------------      ---------] DARRELL E. STAMPER 04/07/92 ]
 ]PF MGR: PALMER B. CHIU    DATE 03/18/92]------------------- -------- ]
 ]       -----------------      ---------] CHAIRMAN, SASCB      DATE   ]
 ]_______________________________________]_____________________________]
 @