 +_____________________________________________________________________
  AUTHOR:                                          DR:              
  L. EITZEN              PASS PROGRAM NOTE             104096       
 ____________________                             __________________
  ORG/PHONE:          OPS NOTE (X)  USER NOTE ( )  DATE:            
  IBM/282-7305             RELEASE NOTE( )             06/07/90     
 ___________________________________________________________________
  OI/FLIGHT EFFECTIVITY:          USER AFFECTED:                     
  OI8B AND SUBS                   CREW (X)  GROUND (X)  DUMP ONLY ( )
 ____________________________________________________________________
         MAJOR SOFTWARE AREA:        OPS MODES AFFECTED:             
 SSW ( )  GNC (X)  VU ( )  SM/PL ( ) G1                              
 ____________________________________________________________________
  SOFTWARE SUB-AREA: RCS, COMMFAULTS, DISP, STATUS                    
 _____________________________________________________________________
  PRINCIPAL FUNCTIONS:  5.16, 6.7, 6.31                               
 _____________________________________________________________________
  TITLE:                                                              
        RCS MANIFOLD COMMFAULT NOT INDICATED IN MM101, MM102          
 _____________________________________________________________________
  DESCRIPTION:                                                        
                                                                      
  OI8B THROUGH OI8F:                                                  
    THE RCS MANIFOLD VALVE COMMFAULT INDICATION WILL NOT BE DISPLAYED 
    ON GNC SYSTEMS SUMMARY I DURING MM101 AND MM102.                  
                                                                      
  OI20:                                                               
    THE RCS MANIFOLD VALVE COMMFAULT INDICATION WILL NOT BE DISPLAYED 
    ON GNC SYSTEMS SUMMARY I AND RCS DISPLAY (SPEC 23) DURING MM101   
    AND MM102.                                                        
                                                                      
  OI21 AND SUBS:                                                      
    THE RCS MANIFOLD VALVE COMMFAULT INDICATION WILL NOT BE DISPLAYED 
    ON GNC SYSTEMS SUMMARY I AND RCS DISPLAY (SPEC 23) DURING MM101.  
                                                                      
    NOTE THAT THE RCS MANIFOLD VALVE COMMFAULT INDICATION WILL BE     
    DISPLAYED IN THE REMAINDER OF OPS 1, BEGINNING IN MM103 ON OI8B   
    THROUGH OI20 AND IN MM102 ON OI21 AND SUBS.                       
 _____________________________________________________________________
 USER RESPONSE:                                                       
                                                                      
  NONE.                                                               
                                                                      
                                                                      
 _____________________________________________________________________
 CONCURRENCE:                           APPROVAL:                    
 IBM:  WYATT COOPER        DATE 06/26/90                             
     --------------------      ---------                             
 FDSD:   SAM ANKNEY        DATE 06/26/90                             
     --------------------      ---------  S. N. HARDEE, JR. 07/11/90 
 PF MGR:   D. W. MAY       DATE 06/29/90------------------- -------- 
        -----------------      --------- CHAIRMAN, SASCB      DATE   
                                                                     
 ____________________________________________________________________
 @