 +_____________________________________________________________________
 ] AUTHOR:            ]     RECONFIGURATION         ] DR:              ]
 ] GEORGE F. SMITH    ]       PROGRAM NOTE          ]  100735          ]
 ]____________________]                             ]__________________]
 ] ORG/PHONE:         ] OPS NOTE ( )  USER NOTE (X) ] DATE:            ]
 ] DP2/X34243         ]      RELEASE NOTE( )        ] MARCH 14, 1991   ]
 ]____________________]_____________________________]__________________]
 ] OI/FLIGHT EFFECTIVITY: OI8D/  ]  USER AFFECTED:                     ]
 ] OI8D/STS-37 RC1, STS-37 FL1   ]  CREW (X)  GROUND (X)  DUMP ONLY ( )]
 ] OI8F/STS-37 RC1               ]                                     ]
 ]_______________________________]_____________________________________]
 ] MAJOR SOFTWARE AREA:    PASS(X) BFS( )] OPS MODES AFFECTED:         ]
 ] SSME**( ) DEU**( ) T&G( ) DFL/FPL**( )]       S2                    ]
 ] TFL**( ) TCS**( ) I-LOAD( ) LEVEL C(X)]                             ]
 ]_____________________________________________________________________]
 ] SOFTWARE SUB-AREA: FDA/DISP                                         ]
 ]_____________________________________________________________________]
 ] PRINCIPAL FUNCTIONS: (JSC-19478-37) 7.6.2/6.1                       ]
 ]_____________________________________________________________________]
 ] TITLE: UNEXPECTED DOWN ARROWS ON SPEC 206 (GRO MONITOR)             ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ] DESCRIPTION:                                                        ]
 ]                                                                     ]
 ] DURING FORMAL CITE TESTS WITH PAYLOAD GAMMA RAY OBSERVATORY, IT WAS ]
 ] DISCOVERED THAT SEVEN GRO TEMPERATURE STATUS PARAMETERS ON SPEC 206 ]
 ] (P52X0049Y THRU P52X0055Y) DISPLAYED A DOWN ARROW IN THE 'OFF'      ]
 ] STATE.  THE CUSTOMER (GRO/GODDARD SPACE FLIGHT CENTER) HAD INTENDED ]
 ] THAT THE DOWN ARROW BE DISPLAYED IN THE 'ON' STATE.                 ]
 ] TWO OF THE PARAMETERS (P52X0053Y, P52X0055Y) DRIVE FAULT SUMMARY    ]
 ] MESSAGES IN THE 'OFF' STATE; AGAIN THE OPPOSITE WAS INTENDED.       ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]USER RESPONSE:                                                       ]
 ]                                                                     ]
 ] THE BI-LEVEL STATE OF THE FDA LOW LIMIT 1 OF SEVEN MEASUREMENTS     ]
 ] WAS INCORRECTLY PROVIDED BY THE PAYLOAD CUSTOMER.  THE BI-LEVEL     ]
 ] STATE CORRECTION WILL BE DONE VIA A TMBU FROM THE GROUND. (IT CAN   ]
 ] ALSO BE DONE BY THE CREW UPDATING SPEC 60).                         ]
 ]                                                                     ]
 ]                                                                     ]
 ]                                                                     ]
 ]_____________________________________________________________________]
 ]CONCURRENCE:                           ]APPROVAL:                    ]
 ]RSOC: SILVIA WERRE        DATE 03/19/91]                             ]
 ]     -------------------      ---------]                             ]
 ]MOD: MICHAEL J. JONES     DATE 03/19/91]                             ]
 ]    --------------------      ---------] DARRELL E. STAMPER  03/21/91]
 ]SW MGR: C.L. STOUGH       DATE 03/19/91]------------------- -------- ]
 ]       -----------------      ---------] CHAIRMAN, SASCB      DATE   ]
 ]_______________________________________]_____________________________]
 @


